Portable professional IPL laser (Intense Pulsed Light) manufactured by Newangie, specialized for hair removal, skin rejuvenation and correction of aesthetic skin problems. IPLS1 uses IPL (Intense Pulsed Light) technology - a broadband light source in the range of 480-1200 nm, which allows you to treat various types of skin problems depending on the selected filter. The device is available in several power configurations (800W/1500W) and offers three operating modes: standard IPL, IPL/E-light and SHR (Super Hair Removal) for maximum versatility. Distinctive features are portability, multi-filter system, cooling system down to -15°C and long service life.
PRINCIPLE OF IPL (INTENSE PULSED LIGHT) IPL (Intense Pulsed Light) is a non-laser broadband light source that uses selective photothermolysis to treat skin.
Broadband light spectrum. IPL emits a broad spectrum of light (430-1200 nm) containing many different wavelengths simultaneously. Different filters allow you to select the optimal spectrum for a specific procedure: - 480-530 nm: acne, blackheads - 530-590 nm: vascular lesions, rosacea - 590-640 nm: pigmentation, rejuvenation - 640-950 nm: hair removal
Selective light absorption. The emitted light is selectively absorbed by target skin structures, depending on the wavelength: - Melanin in hair and hair follicles absorbs light 640-950 nm - Oxyhemoglobin in blood vessels absorbs light 530-590 nm - Bacterial porphyrins in acne absorb light 420-480 nm - Water-loving chromophores (melanin, water) absorb the combined spectrum - Surrounding tissues lacking these components remain undamaged.
Photothermal effect. The absorbed light energy is converted into thermal energy, which: - Heats the target structure to destruction (for hair - the hair follicle, for vessels - the vessel, for pigmentation - the pigment cell) - Traditional IPL uses one powerful pulse that quickly heats the target - SHR uses several weak pulses (In-Motion technique), gradually heating the skin High temperature causes: - For hair follicles: destruction of stem cells, matrix and papilla, leading to permanent hair reduction - For vessels: coagulation of vascular wall proteins, leading to cessation of blood supply - For pigmentation: melanin denaturation and activation of fibroblasts to produce new collagen - For acne bacteria: destruction of Propionibacterium acnes and stimulation of healing
Recovery and results. After the procedure, the body removes fragmented pigment and destroyed tissues through the lymphatic system. Results appear progressively over several weeks.
TECHNICAL SPECIFICATIONS NEW ANGIE IPLS1 PORTABLE
Maximum power supply: 1000 W (power source) Wavelengths (standard): 480 nm, 550 nm, 640 nm Wavelengths (optional): 430 nm, 515 nm, 560 nm, 590 nm, 695 nm, 750 nm Light spot size: 12×30 mm (standard), also 10×40, 10×10, 6 mm Fluence (energy density): 1-50 J/cm² (adjustable) Pulse repetition rate: 1-10 Hz (adjustable) Pulse duration: 1-10 ms (adjustable) Pulse interval: 5-100 ms Lamp life: 1,000,000 flashes Cooling system: Air + water + heat exchanger (three levels) Handpiece cooling temperature: Down to -15°C Display: 12.1-inch capacitive touch screen Operating modes: IPL, IPL/E-light, SHR Languages: Russian, English (and others) Functions: Automatic parameter adjustment based on skin and hair type Input voltage: AC 220V±10% 50/60 Hz OR 110V±10% 50/60 Hz Portability: Mobile device, easily transportable
APPLICATION AREA
Hair removal - All body parts: underarms, legs, arms, back, chest, abdomen, face, bikini area - All hair types: light, dark, curly, straight (except completely white) - All skin types: thanks to 640-950 nm waves and SHR technique - Mechanism: selective absorption by melanin in the hair follicle followed by destruction
Acne and problem skin treatment - Acne: bacterial acne, hormonal acne - Pimples and blackheads: effective removal thanks to porphyrins - Inflamed skin: reduction of inflammation and bacterial count
Skin rejuvenation and photolifting - Wrinkles: stimulation of collagen and elastin production by fibroblasts - Skin tone: tightening and lifting due to new collagen - Pigmentation spots: removal of age spots, freckles - Uneven texture: smoothing of skin relief - Mechanism: 530-640 nm activate fibroblasts and improve microcirculation
Vascular problem treatment - Rosacea: capillary proliferation, red vascular networks - Spider veins: telangiectasias and varicose veins - Skin redness: erythema, persistent redness - Mechanism: 530-590 nm absorbed by oxyhemoglobin, coagulating the vessel
Pigmentation removal - Pigmentation spots: age spots (lentigo), birthmarks - Freckles: removal of ephelides - Hyperpigmentation: evening out skin color - Mechanism: 590-640 nm absorbed by melanin in pigment cells
Procedure protocol - Assessment of patient's skin type (freshness, hair type, presence of contraindications) - Selection of appropriate filter (480, 550 or 640 nm for standard procedures) - Selection of mode (IPL, IPL/E-light, SHR) - Shaving the area 24 hours before procedure (for hair removal) - Skin cleansing and makeup removal - Application of coupling gel - Eye protection (goggles for patient and operator) - Procedure performance: - Setting energy parameters (1-50 J/cm²) according to skin type - Setting frequency (1-10 Hz) - Setting cooling temperature (5 levels) - Setting mode (SHR recommended for hair - more comfortable) - Activation with foot pedal or screen button - Treating the area with systematic overlapping lines - Post-procedure care: - Application of soothing gel or cream - Avoiding water for 24 hours - Using SPF 50+ for 2 weeks - Avoiding hot baths, saunas, pools - Interval between procedures: 4-8 weeks - Typically 6-10 procedures required for hair removal
PACKAGE CONTENTS
Basic package includes: - Main host unit (control and cooling system) - IPL working handpiece (with filters) - Three optical filters (480 nm, 550 nm, 640 nm) - 12.1-inch touch LCD screen - Foot switch (for procedure activation) - Patient eye masks (1 pair) - Operator protective goggles (1 pair) - Funnel + water pipes + connectors (for water) - Overflow device + water pipe (for water circulation) - Hex key (for maintenance) - Power cord (220/110V) - User manual (Russian, English)
CONTRAINDICATIONS
Absolute contraindications (use PROHIBITED): - Pacemaker or heart rhythm driver - Artificial bones, metal implants - Silicosis - Alcohol intoxication, high fever - Mental illness, epilepsy - Severe arterial hypertension, cardiovascular disease - Pregnancy - Cachexia, malignant tumors
Relative contraindications (only under specialist supervision): - Menstruation - Coagulation disorders, skin inflammation - Weakened immune system - History of scar formation - Areas with cosmetic implants - Diabetes mellitus
ADVANTAGES
Portability. Mobile device, easily moved between salons or for off-site work. Weight 37.5-60 kg makes it transportable.
Multi-filter system. 6 filters in the standard set + optional filters for any type of skin problem.
SHR mode. Revolutionary technique for more comfortable and effective hair removal.
Long xenon lamp life. 1 million flashes without energy decay.
Powerful cooling. Down to -15°C ensures maximum patient comfort.
Versatility. One device for hair, acne, vessels, pigmentation, rejuvenation.
Safety for dark skin. IPL and especially SHR mode are safe for all skin types.